§11.4.

Fetch Streams

11.4.1. Fetch Header

When a stream begins with FETCH_HEADER, all objects on the stream belong to the track requested in the message identified by Request ID.

FETCH_HEADER {
  Type (vi64) = 0x5,
  Request ID (vi64),
}
Figure 28: MOQT FETCH_HEADER

Each Object sent on a FETCH stream after the FETCH_HEADER has the following format:

{
  Serialization Flags (vi64),
  [Group ID Delta (vi64),]
  [Subgroup ID (vi64),]
  [Object ID Delta (vi64),]
  [Publisher Priority (8),]
  [Properties (..),]
  Object Payload Length (vi64),
  [Object Payload (..),]
}
Figure 29: MOQT Fetch Object Fields

The Serialization Flags field defines the serialization of the Object. It is a variable-length integer. When less than 128, the bits represent flags described in Section 11.4.1.1. When 128 or greater, the value signals a range indicator; the defined values are:

Reserved Serialization Flags values:

Table 8
Value Meaning
0x8C End of Non-Existent Range
0x10C End of Unknown Range
0x20C End of Timed-Out Range

Any other value 128 or greater is a PROTOCOL_VIOLATION.

11.4.1.1. Flags

Subgroup ID encoding (bits 0-1, mask 0x03): The two least significant bits of the Serialization Flags form a two-bit field that defines the encoding of the Subgroup ID.

Table 9
Value Meaning
0x00 Subgroup ID is zero
0x01 Subgroup ID is the prior Object's Subgroup ID
0x02 Subgroup ID is the prior Object's Subgroup ID plus one
0x03 The Subgroup ID field is present

Independent flag bits: Each of the following is an independent boolean; a set bit (1) indicates the corresponding condition is true.

Table 10
Bitmask Condition if set Condition if not set (0)
0x04 Object ID Delta is present Object ID is the prior Object's ID plus one
0x08 Group ID Delta is present Group ID is the prior Object's Group ID
0x10 Priority field is present Priority is the prior Object's Priority
0x20 Properties field is present Properties field is not present
0x40 Datagram: ignore the two least significant bits Decode the Subgroup ID as indicated by the two least significant bits

The first Object MUST include a Group ID Delta and Object ID Delta, and these values are the absolute Group ID and Object ID. If the first Object in the FETCH response uses a flag that references fields in the prior Object, the Subscriber MUST close the session with a PROTOCOL_VIOLATION.

If the Group ID Delta field is present on an Object other than the first, the Group ID is computed from the Group ID Delta and the prior Object's Group ID. If the Group Order is Ascending, the Group ID is the prior Object's Group ID plus the Group ID Delta + 1. If the Group Order is Descending, the Group ID is the prior Object's Group ID minus the (Group ID Delta + 1). If the computed Group ID would be less than 0 or greater than 2^64-1, the Subscriber MUST close the Session with error 'PROTOCOL_VIOLATION'.

When the Group ID Delta field is present, the Object ID is the value of Object ID Delta if present. When the Group ID Delta field is not present, the Object ID is the prior Object's ID plus the Object ID Delta if present. If Object ID Delta is not present, the Object ID is the prior Object's ID plus one, regardless of which group it belongs to. If the computed Object ID would be greater than 2^64-1, the Subscriber MUST close the Session with error 'PROTOCOL_VIOLATION'.

The Object Properties structure is defined in Section 11.1.2.

When encoding an Object with a Delivery Mode of "Datagram" (see Section 11.1.2), the object has no Subgroup ID. The publisher MUST SET bit 0x40 to '1'. When 0x40 is set, it SHOULD set the two least significant bits to zero and the subscriber MUST ignore the bits.

11.4.1.2. End of Range

When Serialization Flags indicates an End of Range (e.g. values 0x8C, 0x10C, or 0x20C), the Group ID and Object ID fields are present. Subgroup ID, Priority and Properties are not present. All Objects with Locations between the last serialized Object, if any, and this Location, inclusive, either do not exist (when Serialization Flags is 0x8C), are unknown (0x10C), or timed out (0x20C).

When an Object follows an End of Range indicator and uses flags that reference the "prior Object", the prior Object fields are determined as follows:

  • Prior Group ID and prior Object ID: The values from the End of Range indicator.

  • Prior Subgroup ID: The Subgroup ID from the last actual Object before the End of Range indicator. If there was no prior Object, using a flag that references the prior Subgroup ID is a PROTOCOL_VIOLATION.

  • Prior Priority: The Priority from the last actual Object before the End of Range indicator. If there was no prior Object, using a flag that references the prior Priority is a PROTOCOL_VIOLATION.