Sign in

§4.2

Time-alignment

MSF Tracks MAY be time-aligned. Those that are, are subject to the following requirements:

  • Tracks advertised in the catalog as belonging to a common render group MUST be time-aligned.

  • The render duration of the first media object of each equally numbered MOQT Group, after decoding, MUST have overlapping presentation time.

A consequence of this restriction is that an MSF receiver SHOULD be able to cleanly switch between time-aligned media tracks at group boundaries.

This is one section of MOQT Streaming Format, rendered per-section for quick reference and citation. The authoritative text is draft-ietf-moq-msf-00 at the IETF.