Sign in
All relays

Nokia Research draft-22

Nokia

moqt.nokiaresearch.com:4443/moq

QUIC WT drafts 20–22 IPv4

Operated by Nokia. The implementation running here has not been published, so everything below describes this endpoint and nothing else. About this endpoint

At a glance

Identifies itself as
StreamForge MOQ v20
Protocols accepted
moqt-22, h3, moqt-21, moqt-20
Media delivery
delivered, first object 3ms
Violations recorded
none

Certificate

Subject
C=FI, L=Espoo, O=Nokia Oyj, CN=*.nokiaresearch.com
Issuer
C=US, O=DigiCert Inc, CN=DigiCert Global G2 TLS RSA SHA256 2020 CA1
Valid until
2027-03-20 136 days left
Trust
Publicly trusted
Verification
Completed with the certificate verified

Control messages

Which control messages this endpoint answered, per draft. An error reply is still an answer — ok and err are both support; what is recorded as missing is a message that got no answer at all. A dash is neither: it means the exchange ended on our side, so nothing about this endpoint was measured there.

Draft SUBSCRIBEFETCHTRACK_STATUSSUBSCRIBE_NAMESPACEPUBLISH_NAMESPACESUBSCRIBE_TRACKSPUBLISH
22 QUIC ✓ err ✓ err ✓ err ✓ ok ✓ ok ✓ ok ✓ ok
21 QUIC ✓ err ✓ err ✓ err ✓ ok ✓ ok ✓ ok ✓ ok
20 QUIC ✓ err ✓ err ✓ err ✓ ok ✓ ok ✓ ok ✓ ok

Media delivery

One publisher and two subscribers, to see whether an object published through this endpoint reaches a client that asked for it.

Object delivered end to end draft 22 · QUIC
Objects delivered
7/7
Groups / subgroups
2 / 3
Subscribe answered
4ms
First object
3ms
Stream framing
streams kept as sent
Second subscriber
Same object delivered to a second subscriber
Offers a track
relay offered the track

Two publishers of one track

Two publishers announce the same namespace and publish the same tracks, one with identical payloads and one with payloads that differ by publisher. Partway through, the publisher serving the subscribers disconnects without notice. A fresh subscription, sent afterwards, shows whether the remaining publisher could still be reached.

Measured draft 22 · QUIC
Publisher Role Announcement Subscribed to Ended by the relay
first publisher disconnected serving The relay accepted it and subscribed to it. accepted, REQUEST_OK in 1 ms differing payloads, identical payloads —
second publisher serving The relay accepted it and subscribed to it. accepted, REQUEST_OK in 1 ms differing payloads, identical payloads —
Track Objects From When the publisher left Ended by
identical payloads each object once 43 delivered — carried on from the other publisher first object 224 ms after —
differing payloads each object once 1 delivered first publisher ended before the publisher left PUBLISH_DONE 18 “track or object is malformed: duplicate location with different payload or properties”

A fresh subscription after the publisher left: delivered, first object in 5 ms.

Specification violations

None recorded. Nothing this endpoint sent broke a requirement the probe checks — which is not the same as saying it implements the draft completely.

Setup parameters

What this endpoint sent back in its setup response, per draft. A parameter with no name is a code point the negotiated draft does not define.

draft 22 · QUIC

  • 0x04 max_auth_token_cache_size = 1048576
  • 0x06 max_filter_ranges = 64
  • 0x07 moqt_implementation = StreamForge MOQ v20
  • 0x08 max_request_updates = 8
  • 0x09 not defined by this draft = 0x00 (max_control_message_size in 23)
  • 0x0a not defined by this draft = 16

draft 21 · QUIC

  • 0x04 max_auth_token_cache_size = 1048576
  • 0x06 max_filter_ranges = 64
  • 0x07 moqt_implementation = StreamForge MOQ v20
  • 0x08 max_request_updates = 8
  • 0x09 not defined by this draft = 0x00 (max_control_message_size in 23)
  • 0x0a not defined by this draft = 16

draft 20 · QUIC

  • 0x04 max_auth_token_cache_size = 1048576
  • 0x06 max_filter_ranges = 64
  • 0x07 moqt_implementation = StreamForge MOQ v20
  • 0x08 max_request_updates = 8
  • 0x09 not defined by this draft = 0x00 (max_control_message_size in 23)
  • 0x0a not defined by this draft = 16

Draft-22 assigns setup options 0x01 to 0x08. Options 0x09 and 0x0a are unassigned there, and a receiver must ignore setup options it does not recognise, so these break no rule; they are not interoperable either.

History

9 sweeps, newest first. A step where the probe build or the measuring location changed is marked, and is not read as a change of the relay.

  • 27 Oct 2026 → 29 Oct 2026 · measured differently

    • Offering a track: not measured → relay offered the track.
SweepReachableDraftsDeliveryOffers a trackViolationsTwo publishers
5 Nov 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
4 Nov 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
3 Nov 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
2 Nov 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
1 Nov 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
31 Oct 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
30 Oct 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
29 Oct 2026yes20, 21, 22Object delivered end to endrelay offered the track—no defects
27 Oct 2026yes20, 21, 22Object delivered end to end———

Notes

  • — The endpoint is up and refused the offered protocols on at least one transport.

Is this your relay?

If something here is wrong, tell us — we keep what each result rests on, so a disputed one gets re-read rather than re-argued. We can also run this against endpoints that are not public.